The Omniace III series from NEC

The RA2300 and RA2800 data acquisition systems allow for long term recording of measured data which can either be stored internally, printed on the fly like a traditional chart recorder or transmitted to a remote PC.

RA2800 - 32 Channel Data Acquisition System (Chart Recorder)

RA2800 data sheet download

RA2800 demo request

RA2800 quotation request

Multi-Channel Measurement up to 32 Channels!
Simple and Excellent Operation!!

Multi-channel Measurement
Direct sensor inputs up to 32 channels (16 slots).
16 digital inputs for measuring various timing signals.
Unique & Easy “Pen-Recorder" Mode
Easy operation like a pen recorder by the touch panel and virtual amp controls.
High-speed and high-quality printout at max 50mm/sec.
Large 12.1" Display
12.1" TFT color LCD display for better visibility of measured data.
Use Same Amps from RA1000 & RA2300
Same AP amplifiers from conventional RA series. 11 types of amps for various signals like voltage, strain, temperature, vibration, pressure, F/V, etc.
Long-term Continuous Recording on HDD Built-in 40GB HDD Provides 60 days Recording
At 10ms sampling on 32 channels

Features

User selectable measurement modes
Users can easily select from five (5) measurement modes:- Pen Recorder mode for real time strip chart recording, HD Recorder mode for long term recording of data to a HDD, X-Y Recorder mode for displaying/recording X-Y correlation of two signals, Multi Recorder mode captures transients while recording steady-state signals, and a Memory Recorder mode for recording fast events.
Simple Operation
A “Virtual" Amplifier Control Panel with “Auto Function" automatic adjustment mode combined with our proven reliable touch panel guarantee accurate data recording and simple operation.
Upright Type (easy setup on a bench top or rack)
Parts configuration for measurement on a bench top or ra ck control, display and printer units on the front; amplifiers and interfaces on the back.
High-speed & High-quality Printing
Real time selectable chart speeds from 50mm/sec to 1mm/min (resolution: 20 dots/mm).
32 channels Analog & 16 channels Digital recording
Input up to 32 channels of analog data via isolated, dual channel, plug-in amplifier modules for a wide variety of signals and sensors. Also, 16 digital input channels measure diverse signal timing and contact status.
Outstanding Search Function
Max/Min, time and other search functions are available for finding required data points fast and easily after long term measurement.
Standard LAN and USB I/F
LAN (100BASE-T) for data communication and USB for connecting to external storage devices are equipped as standard interfaces.

Back to top...

RA2300 - 16 Channel Data Acquisition System (Chart Recorder)

RA2300 data sheet download

RA2300 demo request

RA2300 quotation request

Simple“Pen-recorder”Mode
Visualized amp. setting-display & touch panel provide simple operation like Pen-Recorder.
Dynamic wave form in Wide Display
12.1 inches TFT color display improves visibility of measuring data
Direct input from Sensors
11 types of input amp. are available for Voltage, Strain, Temp, Vibration,Pressure, F/V and other signal input.
Large size HDD like 120days-recording
Built-in large capacity 40GB HDD enables 120 days-recording (based on sampling speed 10ms, 16ch)
High-speed thermal printing
Chart speed 100mm/s (recording density : 20 dots/mm) to 1mm/min (recording density 80 dots/mm) is selectable.
16 ch Analog + 16 ch Digital
Max. 16ch signal inputs (8 slots) are prepared or various sensors. And 16ch Digital are available separately from these input slots at option, for measurement of diverse signal-timing and contact-condition.
Standard LAN and USB I/F
LAN (100BASE-T) for data communication, and USB (1.1) for connecting to external storage device are equipped as standard I/F.
 

Select most suitable measurement mode for your application
5 measurement modes are available, such as Pen-Recorder like pen-writing recording, HD-Recorder for long term recording. Each measurement mode is dedicated for each application. OMNIACE III RA2300 offers simple and certain operation for exact data acquisition.

Select Mesuring Mode

Selection of input modules according to measurement requirements...

TC/DC amp (AP11-107)
This amp can be used as a thermocouple amp or DC amp. When temperature measurement using a thermocouple amp and voltage measurement using a DC amp are necessary, this amp is useful because no amp replacement is required. Moreover, four types of thermocouples, R, T, J, and K, can be connected and high-speed temperature measurement as fast as 10 µs is possible. This amp contains one channel per unit.

Event amp (AP11-105)
This amp is a logic amplifier that can input eight channels of voltage or contact signals. It is useful for measuring timing or contact signals.
Voltage input: Input voltage 0 to 24 V
H level: 2.5 V or higher
L level: 0.5 V or lower
Contact input:
Open: 2 k or higher
Short: 250 or lower

2-ch AC strain amp (AP11-104)
This amp is a 2-channel amplifier that inputs signals from strain gauges or strain gauge based sensors. Due to the AC bridge type, it features high noise resistance(against the noise caused by the line voltage), high stability, and a high resolution of 16 bits. Low-noise measurement is possible for measurement using strain gauges, which do not have any shielded wires.
Auto-balance
Bridge voltage: 5 kHz, 2 V rms
Response frequency: 0 to 2 kHz
Gauge factor adjustment function: 1.9 to 2.2

2-ch DC strain amp (AP11-110)
This amp is a 2-channel amplifier that inputs signals from strain gauges or strain gauge based sensors. Due to the DC bridge type, it features measurement of high-speed strain signals at a high resolution of 16 bits.
Auto-balance
Bridge voltage: 2 VDC, 5 VDC
Response frequency: 0 to 50 kHz

2-ch vibration/RMS amp (AP11-109)
This is a 2-channel amplifier that features a constant-current power supply for amp-embedded sensors, an RMS conversion function, and a band-pass filter.The RMS function in this amp is effective for monitoring the basic frequency level fluctuation in rotation equipment and the fluctuation of the AC power level.For vibration measurement, an amp-embedded charge sensor can be directly connected to this amp unit. For voltage measurement, 500 V (DC or AC peak values)can be directly input. In addition, the band-pass filter offers filtering of necessary frequencies to perform the RMS conversion so that clear waveforms for judgment are available.
Power for sensor: 2 mA/18 V or higher
Voltage measurement range: 100 mV to 500 V
Band-pass filter: -24 dB/oct
A/D: 16 bits

2-ch FFT amp (AP11-102)
This is a 2-channel amplifier that incorporates an anti-aliasing filter required for the FFT processing and the power for an amp-embedded sensor (constant current).The anti-aliasing filter has a dropout feature at -72 dB/1.5 fc so that the aliasing generated in FFT can be eliminated.
Power for sensor: 2 mA/18 V or higher
Voltage measurement range: 100 mV to 500 V
A/D: 16 bits
Fmax: 40 kHz

F/V converter (AP11-108)
This unit offers frequency-to-voltage conversion, which is useful in recording rotation changes and revolutions in rotation equipment.
Input frequency: 10 kHz max.
Response time: 20 ms (Range of 10 kHz)

2-ch high-resolution amp (AP11-101)
This is a DC amp that can record at a high resolution of 16 bits. Channels are isolated from each other and have a withstand voltage for input of 500 V max. (DC or AC peak values). This amp contains two channels per unit.

2-ch high-speed DC amp (AP11-103)
This is a DC amp that can acquire data at a high-speed sampling rate of 1 µs. Channels are isolated from each other and have a withstand voltage for input of 500 V max. (DC or AC peak values). This amp contains two channels per unit.

2-ch TC/DC amp (AP11-106)
This amp can be used as a thermocouple amp or DC amp. When temperature measurement using a thermocouple amp and voltage measurement using a DC amp are necessary, this amp is useful because no amp replacement is required. Moreover, five types of thermocouples, R, T, J, K, and W can be connected and high-speed temperature measurement as fast as 10 µs is possible. Channels are isolated from each other and have an input voltage of 50 V max. (DC or AC peak values). This amp contains two channels per unit.

Back to top

Back to products page

Page content © NEC Avio Infrared Technologies Co., Ltd. 2008