| Remote Sense |
The maximum load line drop is up to the full voltage rating of the supply. The drop in the load leads subtracts from the maximum voltage available for the load except as follows: maximum rated voltage is available at the load and voltage regulation specifications apply for line drops of<1V on DLM5-75 and DLM8-75, <2V for all other DLM600 models and DLM3K/4K models rated 5V to 16V, and <5V for all other DLM3K/4K models. |
| Remote Programming |
Voltage, current (0-100%) and OVP (5-110%) of full scale can be programmed by selectable 0-5VDC, 0-10VDC, or 0-5kΩ |
| Remote Monitoring |
Voltage or current can be monitored with user selectable ranges, scaled to 0-5 VDC or 0-10 VDC |
| Operational Features |
Master/slave parallel operation, up to 4 units of the same model can be connected in parallel, with active current sharing control. Series operation, multiple units of the same model can be connected in series, limited by 300Vpk between either output terminal and chassis. |
| Software |
IVI-COM, LabVIEW® or LabWindow®/CVI driver for Ethernet and IEEE-488.2 |
| Regulatory Compliance |
CE Compliant:
• Low Voltage Directive (73/23/EEC) using EN 61010-1, and
• EMC Directive (89/336/EEC) using EN 61326 Certified to
UL 61010-1, CSA C22.2 No. 61010.1 and IEC/EN 61010-1 |
|
 |
|
 |
|
| Voltage and Frequency |
90-132 VAC or 180-264 VAC max, auto ranging,
47-63 Hz, single phase, 2-wire plus ground |
| Current |
11A maximum at 115VAC, 6A maximum at 230 VAC |
| Connector |
IEC 320 with detachable line cord |
| Power Factor |
0.6, typical at full load; dependent on the impedance of the AC input. |
|
 |
|
 |
|
| Line Regulation |
Voltage: 0.005% of V max + 2 mV
Current: 0.01% of I max + 2 mA
See table for input voltage variation over the AC input voltage range, with constant rated load. |
| Load Regulation |
Voltage: 0.005% of V max + 2 mV
Current: 0.02% of I max + 5 mA
See table For 0-100% load variation, with constant nominal line voltage |
| Transient Response |
500 μs to steady-state output voltage (within 0.1% of Vmax) for 50-100% or 100-50% load change |
| Stability |
±0.05% of maximum voltage or current over 8 hours after 30 minute warm-up time at fixed line, load and temperature |
| Efficiency |
84% typical at maximum output power; 82% typical for DLM 5-75 and DLM 8-75 |
| Temperature Coefficient |
0.02%/°C of maximum output voltage, 0.03%/°C of maximum output current. Change in output per °C change in ambient temperature, with constant line and load. |
|
 |
|
 |
|
| Dimensions |
Width:
8.5” (216 mm) |
|
Height:
1U or 1.75” (44 mm) |
|
Depth:
17” (432 mm) Option M6 depth 20” (508 mm) |
|
 |
|
 |
|
| Weight |
9.7 lbs. (4.4 kg) |
| Shipping Weight |
12.7 lbs. (5.8 kg) |
|
 |
|
 |
|
 |